Arbet - Styrofoam board Facade Classic EPS 045

Average grade: 0 / 0 reviews
Classic facade expanded polystyrene boards can be used in applications requiring low mechanical loads, in particular for thermal insulation in the following places: - walls made using the "light wet" (BSO, ETICS) method or "light dry", - frame wall surfaces, - gaps in closed or ventilated three-layer walls, - wreaths, jambs, lintels and other places exposed to thermal bridges, - balcony loggias, - sandwich walls; - continuous outer layers of skeletal walls, - wreaths in the formwork method lost for plaster, - floors from below with the "light wet method", - reinforced concrete floors, - steep roofs under and between rafters. In particular for thermal insulation in the following places: - diaphragm walls with ventilated and non-ventilated air gap, - expansion joints in constructions, - in internal partition walls, - walls in skeletal construction with cladding, - floors from below with cladding, - floors between joists - light skeletal ceilings with cladding, - insulation between rafters, - ventilated roofs.
Save amount -
zł196.80 zł196.80
Tax included

Najniższa cena z ostatnich 30 dni: zł196.80 brutto. (zł160.00)

On product inquiry
cennikowa cena jednostkowa netto
zł231.00
za m3
cennikowa cena jednostkowa brutto
zł284.13
za m3
promocyjna cena jednostkowa netto
zł160.00
za m3
promocyjna cena jednostkowa brutto
zł196.80
za m3
całkowita cena cennikowa netto
zł231.00
za 1 m3
całkowita cena cennikowa brutto
zł284.13
za 1 m3
całkowita cena cennikowa netto
zł160.00
za 1 m3
całkowita cena cennikowa brutto
zł196.80
za 1 m3

Products description

Classic facade polystyrene boards can be used in applications requiring low mechanical loads, in particular for thermal insulation in the following places:

  • walls made using the "light wet" (BSO, ETICS) method or "light dry" method,
  • surfaces of skeleton walls,
  • crevices of closed or ventilated three-layer walls,
  • wreaths, jambs, lintels and other places exposed to thermal bridges,
  • balcony loggias,
  • layered walls;
  • continuous outer layers of skeleton walls,
  • wreaths in the formwork method lost to plaster,
  • floors from below with the "light wet method",
  • reinforced concrete floors,
  • steep roofs under and between the rafters.
  • In particular, for thermal insulation in the following places:
    • diaphragm walls with ventilated and non-ventilated air gap,
    • expansion joints in constructions,
    • in internal partitions,
    • walls in frame construction with cladding,
    • floors from below with cladding,
    • floors between joists,
    • light skeleton ceilings with cladding,
    • insulation between rafters,
    • ventilated flat roofs.

attention

Milled edges "overlapped": surcharge 8.00 PLN / m3. Please provide information about the thickness and the method of milling the edges of the panels in the comments to the order. Plate thickness range: from 10 to 300 mm. Due to frequent price movements, for reasons beyond our control, please confirm the price each time you buy.

Specification

width
500 mm
fire classification - reaction to fire
E
thermal conductivity λ
0,045 W/mK
length
1000 mm
thickness range
10 - 300 mm
thickness (dimensional tolerance class)
± 1 mm
length (dimensional tolerance class)
min(± 0,6%; ± 2) mm
width (dimensional tolerance class)
min(± 0,6%; ± 2 mm) mm
squareness (dimensional tolerance class)
± 5/1000 mm/mm
flatness (dimensional tolerance class)
± 15 mm
edge finish
proste
bending strength BS75
>=50 kPa
dimensional stability under constant normal laboratory conditions DS(N)2
± 0,5 %
Dimensional stability under specified temperature and humidity DS(70,-)2
<= 3 %
MPN
15520

Download

Deklaracja Zgodności Fasada Classic Golub

Download file

Reviews

0 / 5

0 clients reviews

Loading...