Tatarek - controller for heating systems RT-08G Tatarek White
Tatarek - controller for heating systems RT-08G Tatarek White
Previous
Next
Index: 33275-65232

Tatarek - controller for heating systems RT-08G Tatarek White

Average grade: 0 / 0 reviews
Control set for operating heating systems fed from a fireplace with a water jacket, with regulation of the air supply to the combustion chamber by means of a cold air damper. It has a bright function display. It provides automatic operation of two central heating circulating pumps and a pump charging the DHW system. A voltage free contact allows you to switch on or off another device (e.g. gas oven).

wymiary

Save amount -
zł1,190.47 zł1,190.47
Tax included

Najniższa cena z ostatnich 30 dni: zł1,190.47 brutto. (zł967.86)

On product inquiry
cennikowa cena jednostkowa netto
zł1,543.00
za szt
cennikowa cena jednostkowa brutto
zł1,897.89
za szt
promocyjna cena jednostkowa netto
zł967.86
za szt
promocyjna cena jednostkowa brutto
zł1,190.47
za szt
całkowita cena cennikowa netto
zł1,543.00
za 1 szt
całkowita cena cennikowa brutto
zł1,897.89
za 1 szt
całkowita cena cennikowa netto
zł967.86
za 1 szt
całkowita cena cennikowa brutto
zł1,190.47
za 1 szt

Products description

Control set for operating the heating system supplied from a fireplace with a water jacket, with regulation of the air supply to the combustion chamber by means of a cold air damper. It has a bright function display. It provides automatic operation of two central heating circulation pumps and a pump for charging the hot utility water system. A voltage free contact allows you to switch on or off another device (e.g. gas oven).

Equipment

  • three water temperature sensors
  • air supply damper
  • mounting box for concealed installation
  • bright function display

Basic controller functions

  • optimization of the combustion process in the fireplace
  • smooth control of the throttle regulating combustion air supply
  • DHW pump control
  • different operating modes for the DHW pump
  • controlling the operation of two circulation pumps
  • the function of blocking another source of heat when the fireplace provides heat to the installation
  • integrated zone thermostat function
  • memory in case of power failure - restoration of previously made settings

Technical data

  • 230 V / 50 Hz power supply
  • no load power consumption 5 W
  • maximum connected power 750 W
  • number of outputs controlling 3 * 250 W / 230 V / 50 Hz pumps
  • one voltage-free control output
  • number of outputs controlling the throttle drive 1 * 5 V / 500 mA / DC
  • quantity sensor in water temperature 3 * KTY81 (0 ... + 100 C)
  • accuracy of temperature measurement 2 C
  • temperature measurement resolution 0.5 C

Reviews