The controller has a proportional controller for cooperation with electric air heaters powered by a single-phase (1 ~ 230 V) voltage with a maximum power of 3.2 kW and a two-phase (2 ~ 400 V) with a maximum power of 6.4 kW and a current intensity of up to 16 A.
Save amount -
zł661.54 zł661.54
Tax included

Najniższa cena z ostatnich 30 dni: zł661.54 brutto. (zł537.84)

On product inquiry
cennikowa cena jednostkowa netto
zł720.00
za szt
cennikowa cena jednostkowa brutto
zł885.60
za szt
promocyjna cena jednostkowa netto
zł537.84
za szt
promocyjna cena jednostkowa brutto
zł661.54
za szt
całkowita cena cennikowa netto
zł720.00
za 1 szt
całkowita cena cennikowa brutto
zł885.60
za 1 szt
całkowita cena cennikowa netto
zł537.84
za 1 szt
całkowita cena cennikowa brutto
zł661.54
za 1 szt

Products description

The controller has a controller proportional to cooperation with electric air heaters powered by a single-phase (1 ~ 230 V) voltage with a maximum power of 3.2 kW and a two-phase (2 ~ 400 V) with a maximum power of 6.4 kW and a current intensity of up to 16 A.

Technical data

  • controller with proportional controller
  • automatic adaptation to supply voltage
  • detection of connected sensor in
  • degree of protection IP20
  • for wall mounting
  • the device should be connected in series between the power source and the electric heater
  • power to the heaters switched on via a triac at zero phase angle to eliminate interference
  • the operating mode is set with a switch under the housing
  • width 150 mm
  • height 80 mm
  • depth 45 mm
  • maximum temperature 30 C

Modes of operation

  • room temperature control in the range of 0-30 C based on the reading of the built-in temperature sensor (Tint)
  • air supply temperature control in the range of 0-30 C or 0-60 C based on the reading of the temperature sensor TJK10K (Tlimit) located in the duct after the heater
  • room temperature control in the range of 0-30 C based on the reading of two sensor in TJK10K (Tlimit, Texh), in this mode the minimum value (0-20 C) and maximum (25-60 C) of the supply temperature controlled by the sensor Tlimit is set using a potentiometer in MIN / MAX inside the housing

The controller enables activation of the night temperature reduction by means of an external potential-free contact connected to the terminal in the Timer, in the range of 0-10 C (NIGHT potentiometer).

Note: TJK10K sensors must be purchased separately.