Tatarek - regulátor pro topné systémy RT -08G Tatarek
Tatarek - regulátor pro topné systémy RT -08G Tatarek
Předchozí
Další
Index: 33274-65217

Tatarek - regulátor pro topné systémy RT -08G Tatarek

Average grade: 0 / 0 reviews
Control set for operating heating systems fed from a fireplace with a water jacket, with regulation of the air supply to the combustion chamber by means of a cold air damper. It provides automatic operation of two central heating circulating pumps and a pump charging the DHW system. A voltage free contact allows you to switch on or off another device (e.g. gas oven).

wymiary

Save amount -
1 154,01 zł 1 154,01 zł
S DPH

Najniższa cena z ostatnich 30 dni: 1 154,01 zł brutto. (938,22 zł)

On product inquiry
cennikowa cena jednostkowa netto
1 415,00 zł
za szt
cennikowa cena jednostkowa brutto
1 740,45 zł
za szt
promocyjna cena jednostkowa netto
938,22 zł
za szt
promocyjna cena jednostkowa brutto
1 154,01 zł
za szt
całkowita cena cennikowa netto
1 415,00 zł
za 1 szt
całkowita cena cennikowa brutto
1 740,45 zł
za 1 szt
całkowita cena cennikowa netto
938,22 zł
za 1 szt
całkowita cena cennikowa brutto
1 154,01 zł
za 1 szt

Products description

Control set for operating the heating system supplied from a fireplace with a water jacket, with regulation of the air supply to the combustion chamber by means of a cold air damper. Has a graphic display. It provides automatic operation of two central heating circulation pumps and a pump for charging the hot utility water system. A voltage free contact allows you to switch on or off another device (e.g. gas oven).

Equipment

  • three water temperature sensors
  • air supply damper
  • mounting box for concealed installation
  • Titanium Design version
  • graphic display

Basic controller functions

  • optimization of the combustion process in the fireplace
  • smooth control of the throttle regulating combustion air supply
  • DHW pump control
  • different operating modes for the DHW pump
  • controlling the operation of two circulation pumps
  • the function of blocking another source of heat when the fireplace provides heat to the installation
  • integrated zone thermostat function
  • memory in case of power failure - restoration of previously made settings

Technical data

  • 230 V / 50 Hz power supply
  • no load power consumption 5 W
  • maximum connected power 750 W
  • number of outputs controlling 3 * 250 W / 230 V / 50 Hz pumps
  • one voltage-free control output
  • number of outputs controlling the throttle drive 1 * 5 V / 500 mA / DC
  • quantity sensor in water temperature 3 * KTY81 (0 ... + 100 C)
  • accuracy of temperature measurement 2 C
  • temperature measurement resolution 0.5 C