Arbet - polystyrenová deska Komfort Facade EPS 042

Average grade: 0 / 0 reviews
Styrofoam facade facade comfort can be used in applications requiring the transmission of light mechanical loads, in particular for thermal insulation in the following places: - walls made by the method of "light wet" (BSO, ETICS)) or "light dry", - surfaces of framework walls, - crevices of closed or ventilated three-layer walls, - wreaths, jambs, lintels and other places exposed to thermal bridges, - balcony loggias, - sandwich walls; - continuous outer layers of skeletal walls, - wreaths in the formwork method lost for plaster, - floors from below with the "light wet method", - reinforced concrete floors, - steep roofs under and between rafters. In particular for thermal insulation in the following places: - diaphragm walls with ventilated and non-ventilated air gap, - expansion joints in constructions, - in internal partition walls, - walls in skeletal construction with cladding, - floors from below with cladding, - floors between joists - light skeletal ceilings with cladding, - insulation between rafters, - ventilated roofs.
Save amount -
206,64 zł 206,64 zł
S DPH

Najniższa cena z ostatnich 30 dni: 206,64 zł brutto. (168,00 zł)

On product inquiry
cennikowa cena jednostkowa netto
242,00 zł
za m3
cennikowa cena jednostkowa brutto
297,66 zł
za m3
promocyjna cena jednostkowa netto
168,00 zł
za m3
promocyjna cena jednostkowa brutto
206,64 zł
za m3
całkowita cena cennikowa netto
242,00 zł
za 1 m3
całkowita cena cennikowa brutto
297,66 zł
za 1 m3
całkowita cena cennikowa netto
168,00 zł
za 1 m3
całkowita cena cennikowa brutto
206,64 zł
za 1 m3

Products description

Styrofoam facade comfort panels can be used in applications requiring the transmission of light mechanical loads, in particular for thermal insulation in the following places:

  • walls made using the "light wet" (BSO, ETICS) method or "light dry" method,
  • surfaces of skeleton walls,
  • crevices of closed or ventilated three-layer walls,
  • wreaths, jambs, lintels and other places exposed to thermal bridges,
  • balcony loggias,
  • layered walls;
  • continuous outer layers of skeleton walls,
  • wreaths in the formwork method lost to plaster,
  • floors from below with the "light wet method",
  • reinforced concrete floors,
  • steep roofs under and between the rafters.
  • In particular, for thermal insulation in the following places:
  • diaphragm walls with ventilated and non-ventilated air gap,
  • expansion joints in constructions,
  • in internal partitions,
  • walls in frame construction with cladding,
  • floors from below with cladding,
  • floors between joists,
  • light skeleton ceilings with cladding,
  • insulation between rafters,
  • ventilated flat roofs.

attention

Milled edges "overlapped": surcharge 8.00 PLN / m3. Plate thickness range: from 10 to 300 mm. Please provide information about the thickness and finish of the panel edges in the commentary to the order. Due to frequent price movements, for reasons beyond our control, please confirm the price each time you buy.

Specification

šířka
500 mm
požární klasifikace - reakce na oheň
E
součinitel tepelné vodivosti λ
0,042 W/mK
délka [mm]
1000 mm
tloušťka (třída rozměrových tolerancí)
± 2 mm
délka (třída rozměrových tolerancí)
min(± 0,6%; ± 3) mm
šířka (třída rozměrových tolerancí)
min(± 0,6%; ± 3 mm) mm
pravoúhlost (třída rozměrových tolerancí)
± 5/1000 mm/mm
rovinnost (třída rozměrové tolerance)
± 15 mm
okrajová úprava
proste
pevnost v ohybu BS75
>= 75 kPa
rozměrová stálost za konstantních normálních laboratorních podmínek DS (N) 2
± 0,2 %
rozměrová stálost za určitých podmínek teploty a vlhkosti DS (70,-) 2
<= 2 %
MPN
10503